- Ear Protector[7]
- Water Filters[7]
- Clinical Analytical Instruments[1]
- Chemical Process Equipment Parts[1]
- Pumps[5]
- Other Lab Supplies[8]
- Funnel[3]
- Test Tube[2]
- Laboratory Heating Equipments[9]
- Testing Equipment[5]
- Spectrometers[1]
- Other Inorganic Chemicals[5]
- Silica[1]
- Other Analysis Instruments[8]
- Gas Analyzers[2]
- Laboratory Furniture[7]
- Dental Equipments[7]
- Water Treatment[1]
- Building Glass[5]
- Formwork[2]
- Medical Rubber[7]
- Moisture Meters[2]
- Temperature Instruments[1]
- Hardness Testers[1]
- Toy Balls[1]
- Valves[2]
- Mixing Equipment[1]
- Plastic Tubes[3]
- Contact Person : Mr. Shanghai ZDAN
- Company Name : Shanghai Zdan International Co., Ltd.
- Tel : 0086-021-64298971
- Fax : 0086-021-64298973
- Address : Shanghai,shanghai,Room 217, No.38, Lane 2049, Pujin Road,Shanghai City(200240), China.
- Country/Region : China
- Zip : 201114
Model GC102AF/AT Gas Chromatograph
Model GC102AF/AT Gas Chromatograph
Characteristics
1.Computer aided temperature control with high accuracy (less than ±0.1°C)2.All control and application parameters, including operation parameters of the detector, can be set up through keyboard. Functions, such as self-diagnosis, switch-off protection, document storage and transaction, limittemperature setup thermal trip valve setup, and FID auto-ignition are incorporated inside of the instrument.3.Large-screen LCD display, supporting Chinese characters, can accurately and clearly present all temperaturecontrol setup values, actual values, TCD working electricity supply, sensitivity of FID magnifier, and etc.4.The instrument supports packed column i.e. on-column sample injection. It is compatible with such devices as instantaneous vaporizing sample injection, gas sample injection with gas sample injection valves, and 0.53mm large diameter capillary column direct sampler.5.Open-end computer system can apply RS-232 interface and N-2000 chromatogram workstation to achieve dual path communication control and data processing.6.Large capacity column (300mm×280mm×270mm) is easy to be installed with packed column and large diameter capillary column.
Performance Indicators
Temperature Control:
1. Temperature control areas: gas chromatogram column, sampler, detector
2. Temperature control range: 15°C-399°C of room temperature (increment by 1°C)
3. Temperature control accuracy: less than ±0.1°C (measured at 200°C)
Flame Ionization Detector (FID):
1. Detection limit:Mt≤1×10-10g/s(sample C16)
2. Drift:≤2×10-12A/h
Thermal Conductivity Detector (TCD):
1. Sensitivity: S≥1500mV.ml/mg(carrier gas: H2 sample: n-Hexadecane)
2. Baseline noise:≤20uV
3. Baseline drift:≤50uV/h
If you want to know more information,please feel free to contact me.
Model GC102AF/AT Gas Chromatograph